Stotles logo
Stale pre-tender

NovecTM HFE7100 Replacement Solvent

Published

Description

SUMMARY 1. We are looking for a replacement for NovecTM HFE7100 that is compatible with fingermark development techniques that target amino acids. We are looking for information on potential solvents that exist on the current market with the desired properties. 2. Additionally we are interested in parties that would be willing to collaborate with us to further develop their existing replacement product to fit our requirements. 3. We are interested in parties that would be willing to develop a new replacement product to fit our requirements. BACKGROUND HFE 7100 has been the carrier solvent recommended by the Fingermark Visualisation Manual (FVM) for both amino acid reagent techniques, Indandione and Ninhydrin. These techniques are the two most prominent techniques used by UK Police to treat porous items and has been reported to be used on up to 50% of items submitted to Fingermark Enhancement Laboratories. In addition to the discontinuation of HFE 7100, a proposed restriction of PFAS chemical manufacture is being considered by the European Chemical Agency (ECHA). These potential restrictions have a significant impact on reformulations of the two porous techniques. Some of our international counterparts currently use flammable solvents such as Petroleum Ether in their formulations. The UK want to avoid using the flammable solvent approach due to the safety and cost implications that would entail. The amount of work and investment in to make current Fingermark Enhancement Laboratories suitably to work with a flammable formulation would not be a viable option for many police forces and would result in the loss of the capability in numerous areas, requiring outsourcing and potential backlogs. Our current formulations are as follows: Indandione formulation 0.25g 1,2 - Indandione 45ml Ethyl acetate 45ml Methanol 10 mL Acetic acid 1 L HFE 7100 1 mL Zinc Chloride Stock Solution Zinc Chloride Stock Solution 0.1 g Zinc chloride 4 mL Ethyl acetate 1 mL Acetic acid Ninhydrin formulation 52 mL Ninhydrin Concentrated Solution 1 L HFE7100 Ninhydrin Concentrated Solution 5 g Ninhydrin 5 mL Acetic acid 45 mL Ethanol 2 mL Ethyl acetate SUBMIT INTEREST AND FEEDBACK Please send interest and feedback to jamcdonald@dstl.gov.uk. Please ensure to review the sensitivity and exposure liability of the feedback you provide to the Authority. Anything discussed via this post is non-committment and subject to contract.

Timeline

Publish date

11 months ago

Buyer information

Defence Science & Technology Laboratory

Contact:
Dstl Commercial Services CT&S Division
Email:
CTS-Transparency@dstl.gov.uk

Explore contracts and tenders relating to Defence Science & Technology Laboratory

Go to buyer profile
To save this opportunity, sign up to Stotles for free.
Save in app
  • Looking glass on top of a file iconTender tracking

    Access a feed of government opportunities tailored to you, in one view. Receive email alerts and integrate with your CRM to stay up-to-date.

  • ID card iconProactive prospecting

    Get ahead of competitors by reaching out to key decision-makers within buying organisations directly.

  • Open folder icon360° account briefings

    Create in-depth briefings on buyer organisations based on their historical & upcoming procurement activity.

  • Teamwork iconCollaboration tools

    Streamline sales workflows with team collaboration and communication features, and integrate with your favourite sales tools.

Stop chasing tenders, start getting ahead.

Create your free feed

Explore similar tenders and contracts

Browse open tenders, recent contract awards and upcoming contract expiries that match similar CPV codes.

Explore other contracts published by Defence Science & Technology Laboratory

Explore more open tenders, recent contract awards and upcoming contract expiries published by Defence Science & Technology Laboratory.

Explore more suppliers to Defence Science & Technology Laboratory

Sign up