Stotles logo
Awarded

prj_4589 - ICA Telemetry Framework

Published

Supplier(s)

HWM Water Limited, Ovarro Ld Ltd, Technolog Limited, HWM Water Limited, Gutermann Ltd, Ovarro Ld Ltd, HWM Water Limited, Technolog Limited, HWM Water Limited, Technolog Limited

Value

35,200,000 GBP

Description

As part of our AMP 7 to AMP 8 Transition and Operational Site Service Procurement Strategy, Southern Water has come to market for strategic partners to support our Instrumentation Automation Control (ICA) Telemetry requirements for our operational sites and network. An ICA Telemetry framework agreement lasting 4 years, with an option to extend for a period of up to 4 years. Region/Network - Southern Water’s region covers Kent, Sussex, Hampshire and Isle of Wight. Resilience - Southern Water has a requirement to ensure 24 hours a day, 7 days a week and 365 days a year, that we can access and maintain our plant, equipment and assets. The Goods and Services under this agreement is divided into lots. Lot Lot 1 – Pressure & Flow Loggers: Southern Water Services (SWS) wishes to procure flow and pressure logging equipment or devices that are used to measure flow and pressure within the potable water network, enabling SWS to monitor live data enabling the use of network operating systems to carry out Calm network operations. Flow devices – Pre-Calibrated, and able to accurately measure flow within the network giving real time l/s performance of the network. Flow devices where possible should record the following: - Flow measurement - Temperature measurement - Pressure measurement - Analytical measurement - Level measurement - Battery Usage / % left - GSM/GPRS/NBIoT Signal Strength Pressure Logging devices - Pre-Calibrated, and able to accurately measure pressure within the network giving real time m/h performance of the network. The simplest loggers record one channel of pressure data and are suitable for locations such as the AZP (Average Zonal Point) or CPP (Critical Pressure Point), however pressure loggers with greater than one channel recording are required. Pressure devices where possible should record the following: - Pressure measurement - Temperature measurement - Analytical measurement - Battery Usage / % left - GSM/GPRS/NBIoT Signal Strength Data acquisition: 1. Flow devices should be logging at a minimum of 15min cycles and be set to transmit this data back to the main server at 15minute intervals. 2. Pressure devices should be logging at 1min cycles and be set to transmit this data back to the main server at 15minute cycles. Data availability and storage costs need to be made available before any procurement is carried out to ensure the most cost effect solution for need is selected. The interval and cycles should be able to be changed remotely to near real time data with this information being available for incident control. Lot Lot 2 – Acoustic Loggers: Leakage detection and location equipment or devices that are used to measure and direct active leakage reduction activities. Leakage localisation devices (units): which identify and prioritise the areas and points of interest of leakage to make the pinpointing of leaks easier. Leakage pinpointing methods: which identify the position points of interest including leaks as accurately as possible. Data acquisition: equipment or devices that gather and store measured data or signals. Data acquisition equipment may include computers, data loggers, network ancillaries, remote terminal units, highspeed timers, random access memory (RAM) devices and USB flash drives. Data processing software: All data processing required to pinpoint the location of the potential point of interest and or leak is to be provided. All raw and processed data is to be made available for access and transfer to SWS. Output displays: Hand-held or on-line displays which are to be used during leak detection operation on site (localisation and pinpointing) with an option for future integration/data transfer into SWS event management platforms. Services: Services associated with recycling and disposal of equipment. Lot Lot 3 – PRV Controllers: Pressure Controller equipment or devices that are used to control Pressure such as Pressure Reduction Valves (PRV’s), Enabling SWS to monitor live data enabling the use of network operating systems to carry out Calm network operations. ressure Controllers Provides optimised calmer network pressures Prolongs the expected life of a distribution network, reducing capital expenditure Flow, time and advanced closed loop control supporting real-time feedback from Cello data loggers installed at critical points Integral multi channel data logger Remote profile configuration Hydraulic-less control, no filters required, low maintenance External battery or externally powered Advanced channel profile and threshold alarms Remote monitoring and control through locally deployed Process Measurement and Control (PMAC) software or web based platform Digital transducers enable water and ambient temperature measurement Data acquisition: Controllers should be logging at a minimum of 1min cycles and be set to transmit this data back to the main server at 15 minute intervals. The interval and cycles should be able to be changed remotely to near real time data with this information being available for incident control. Data processing software: All raw and / or processed data is to be made available for access and transfer to SW Waternet system. Output displays: Hand-held or on-line displays with full integration into SWS event management platforms. IP68 Monitors, cabling and connections / ancillaries will be IP68 rated to prevent the ingress of dirt particles and liquid into the equipment. Lot Lot 4 – Transient Loggers: Southern Water Services (SWS) have procured pressure transient loggers previously and SWS now wishes to procure additional pressure transient devices that are used to monitor pressure transient waves within a water network which are believed to cause bursts and leakage, making them a key part of SWS’s leakage control effort. Pressure Transient devices (units): which identify and triangulate the source of pressure transients waves. Data acquisition: Pressure is to be measured at a frequency of at least 60 samples per second (60Hz) as well as providing summarised data as average, minimum, and maximum pressures in 1-minute intervals (or as required by SWS). Internal clocks are to be aligned to sub-second accuracy. Data processing software: Sufficient software to convert the raw pressure measurements into events based on pre-defined criteria (magnitude, duration, frequency) and provision of summaries (average, minimum, maximum for 1-minute intervals). Output displays: The Web Hosted Platform can be accessed as a web page with an option for further integration/data transfer into SWS event management platforms in the future. Services: Analytical support for interpretation of the logger results and logger management and deployment if required. Support during installation and setting up: Advice and recommendations for best positioning and setting up of the units. IP68: Monitors, cabling and connections / ancillaries will be IP68 rated to prevent the ingress of dirt particles and liquid into the equipment. Pre-assembled system shall be provided ready to be used by SWS Framework contractors.

Timeline

Award date

3 months ago

Publish date

3 days ago

Buyer information

Southern Water Services Ltd

Contact:
Paul Knight
Email:
Paul.Knight@southernwater.co.uk

Explore contracts and tenders relating to Southern Water Services Ltd

Go to buyer profile
To save this opportunity, sign up to Stotles for free.
Save in app
  • Looking glass on top of a file iconTender tracking

    Access a feed of government opportunities tailored to you, in one view. Receive email alerts and integrate with your CRM to stay up-to-date.

  • ID card iconProactive prospecting

    Get ahead of competitors by reaching out to key decision-makers within buying organisations directly.

  • Open folder icon360° account briefings

    Create in-depth briefings on buyer organisations based on their historical & upcoming procurement activity.

  • Teamwork iconCollaboration tools

    Streamline sales workflows with team collaboration and communication features, and integrate with your favourite sales tools.

Stop chasing tenders, start getting ahead.

Create your free feed

Explore similar tenders and contracts

Browse open tenders, recent contract awards and upcoming contract expiries that match similar CPV codes.

Explore other contracts published by Southern Water Services Ltd

Explore more open tenders, recent contract awards and upcoming contract expiries published by Southern Water Services Ltd.

Explore more suppliers to Southern Water Services Ltd

Sign up